Number of channel: Dual channels
Input ratings(0~40°C):
- – Voltage: 0~150V
- – Current: 0~2A; 0~20A
- – Power: 2x200W
CV mode:
- – Range: 0~18V, 0~150V
- – Accuracy: ±(0 .05%+0 .1%FS)
CC mode:
- – Range: 0~2A; 0~20A
- – Accuracy: ±(0.05%+0.05%FS)
CR mode:
- – Range: 0.05Ω~7.5KΩ
- – Accuracy: 0.1%+0.5%FS
CP mode:
- – Range: 200W
- – Accuracy: 0.1%+0.5%FS
Dynamic mode:
- – T1&T2: 100µS~3600S
- – Accuracy: 5µs±100ppm
- – Slope: 0.001 ~0.15A/µs
Readback voltage:
- – Range: 0~18V, 0~150V
- – Accuracy: ±(0.05%+0.1%FS)
Readback current:
- – Range: 0~2A, 0~20A
- – Accuracy: 0.05%+0.1%FS
Readback power:
- – Range: 200W
- – Accuracy: ±(0.1%+0.5%FS)
- Over-temperature protection: ≥95°C
- Resolution: 1mV/1mA
- Basic mode: CC/CV/CR/CP
- Test mode: Dynamic mode, list mode, battery test
- System setup: Language: Chinese/English, key tone setting
- Data storage: 60 sets of data memory
- Interface & protocol: RS-232 interface and SCPI protocol
- Power: 110V/220V; 50/60Hz
- Display: 2.8 inches LCD
- Weight: 3.6kg
- Size: 300mm x 88mm x 174mm
Standard accessories:
- – International standard power cord
- – 250V/0.5A fuse (only for 110V input voltage)
Optional accessories:
- – Power cable 3C
Avis
Il n’y a pas encore d’avis.